    zhejiang yisoo electric co., ltd.

    Limit Switch

    View more specifications Limit Switch for you
    Model No.: TZ-8107 
    Place of Origin: Zhejiang 
    Brand Name: CNTD 
    Certificate: CE 

           or 
    1 2 3
     Description
    Payment & Shipping Terms:
    Unit Price:US$3.6
    MOQ: 500 pcs
    Supply Capacity:
    Delivery Date: 30days
    TZ-8 Limit Switch
     
     

    Features
    ◆ Double circuit type of limit switch
    ◆ Highly rigid construction, consists of intensive plastic and aluminum cast (Head and cover snugly fit in box)
    ◆ Small volume, water-proof and oil-proof construction
    ◆ Built-in basic switch with double spring mechanism, longer mechanical life
    ◆ Smooth operation with greater OT
    ◆ Easy-to-wire circuit opening design
    ◆ Wide varity of actuators, easily use


    Ratings

    Rated Voltage

    Noninductive Load
    (A)

    Inductive Load
    (A)

    Resistance Load

    Lamp Load

    Inductive Load

    Motor Load

    NC

    NO

    NC

    NO

    NC

    NO

    NC

    NO

    125VAC
    250VAC
    500VAC

    5
    5

    5
    5

    1.5
    1

    0.7
    0.5

    3
    3

    3
    3

    2
    1.5

    1
    0.8

    8VDC
    14VDC
    30VDC
    125VDC
    250VDC

    5
    5
    5
    0.4
    0.2

    5
    5
    5
    0.4
    0.2

    3
    3
    3

    3
    3
    3

    5
    4
    4

    4
    4
    4

    3
    3
    3

    3
    3
    3

    Inrush Current

    N.C: below 24A, N.O: below 12A

    NOTES:
    1.Inductive load has a power factor of 0.4 min.(AC) and a time constant of 7 msec.max.(DC).
    2.Lamp load has an inrush current of 10 times the steady-state current,while motor load has
    an inrush current of 6 times the steady-state current.

    Characteristics

    Operation speed

    0.5mm-50cm/sec

    Operating frequency

    Mechanical: 120 operations/minute, Electrical: 30 operations/minute

    Contact resistance

    25mΩ max. (initial value)

    Insulation resistance

    100mΩ min. (at 500VDC)

    Dielectric strength

    1000VAC, 50/60HZ for 1 minute between terminals of the same polarity

    1500VAC, 50/60 HZ for 1 minute between currentcarrying
    and non-current-carrying metal parts

    1500VAC, 50/60 HZ for 1 minute between each terminal and ground

    Vibration

    10-55HZ,1.5mm double amplitude

    Shock

    Mechanical durable: 1, 000m/Sec2 (about 100G’S)
    Malfunction: 300m/Sec2 (about 30G’S)

    Ambient temperature

    -5℃ to +65℃

    Humidity

    <95% RH

    Life

    Mechanical: 10,000,000 operations above
    Electrical: 500,000 operations above

    Weight

    About 130 to 190g

    Degree of protection

    IP65